Direct answer: When a reflow oven stops mid-run, the boards inside it do not share one fate. A board in the preheat zone has paste that never melted; a board in the soak zone has flux that is being used up; a board at peak has joints that are half formed; a board in cooling has joints that are solidifying outside their qualified cooling rate. They cannot be judged as one batch, and they cannot be saved by one rule. The only sound decision is board by board: where was this board in the tunnel, how far through its profile had it got, and what do its own paste datasheet, its components’ datasheets and its own measured profile say about a second heat exposure? There is no single temperature, time or profile that is a safe re-run standard for every board, and no source publishes one. Some boards are re-run candidates, some need component-level rework, and some belong in scrap or in the material review board’s hands. This article shows how to tell them apart, what to inspect before deciding, and what to record so the re-run boards never disappear back into the good population unmarked.
The oven stops in the middle of a run. The conveyor is still, the heaters are cooling, and somewhere inside the tunnel there are boards at every stage of their profile — some barely warm, some with paste half melted, some with joints that were seconds away from being finished. The question that matters is not how fast the oven can be restarted. It is what has already happened to the boards inside it, and which of them can still become good boards. Get that decision wrong in one direction and you scrap boards that could have been saved. Get it wrong in the other and you ship boards whose joints were never properly formed, and the failure shows up weeks later, in a customer’s hands, where it costs far more than a scrapped board ever would. This article is the decision guide for that moment, and the next piece in our line-economics series — after staffing, changeover cost, turnkey quotes, OEE, the maintenance calendar, board testing, downtime logging, mid-batch substitution approval, throughput, scrap cost, the end-of-life decision, the second-mounter decision, the used-line purchase and job kitting. It is about the boards already inside a hot oven when it stops, not about fixing the oven, and not about the first hour of a breakdown in general.
Five boundaries first, so the rest of the article is read correctly. First, this article starts where the first-hour triage ends. The companion piece on our WordPress site, “When a Machine Breaks Mid-Order: The First Hour” (20 November 2026), covers stopping safely, naming the failure, and deciding whether to run degraded, move the work or stop — that work is assumed done here, and none of it is re-taught. Second, no price appears in this article and no cost figure is presented as a standard: what a scrapped or reworked board costs belongs to the costing decision covered in “What a Bad Board Really Costs”, and it is not re-priced here. Third, no single temperature, time or profile is presented as a safe re-run standard, because none exists: whether a board can be re-run follows that board’s own profile data and the solder paste and component suppliers’ data, and the article says so explicitly wherever the question arises. Fourth, every worked example is marked as an example, with its assumptions stated next to it; none of them is a measurement from a real line and none of them is a record of a real customer’s board or batch. Fifth, JHIMS sells the R10 reflow oven; it does not sell a rework or re-run service, and nothing here is an offer of one.

The JHIMS R10 reflow oven at its board-entrance end (official installation video, first frame). An installation photograph, not a stopped oven — no frame in the installation video series shows a board inside the tunnel.
The first minutes after a stop are the ones where a second, worse problem is most easily created. A hot oven does not cool instantly, and a board left inside after a stop can be damaged by the residual heat while nobody is looking at it. Do not put a hand inside a hot tunnel to pull boards out. Oven manuals say this in plain language: wait for the cool-down the manual specifies for your model before any manual intervention, and use heat-proof gloves to handle boards that have been in the heat. One manufacturer’s manual puts the wait at thirty minutes before manual intervention; a bench-oven guide advises against opening the door or touching the board until its sensors read below 80 °C. Those two numbers are not the same number, and neither of them is a universal safe temperature — they belong to different oven models, and the only safe wording that covers every oven is to follow the manual for the oven in front of you.
Stop the oven properly at its own panel rather than by cutting power to the whole machine, unless the manual tells you otherwise for that stop. The panel is where the oven’s own stop, alarm and cool-down behaviour is controlled, and an uncontrolled power cut takes away the conveyor and the fans at the same time as the heat, leaving the boards exactly where they stopped with no way out. If the oven has a board-drop or board-jam alarm, follow the alarm procedure in the manual: on at least one manufacturer’s oven, dropped boards must be removed from the process tunnel before restart, and board counts reset when the oven restarts. Do not improvise a procedure the manual does not describe.

The R10 operator panel: emergency-stop button and start-up indicator (official installation video frame). Stop the oven at its own panel where the manual says so — do not simply cut power to the machine.
While the oven cools, do the three things that make the later decision possible. First, record the stop: the time it happened, the recipe that was running, which boards were in the tunnel and, as far as anyone can tell, where each one was. The downtime log is the place for that record — our piece on logging downtime, “Where the Hours Go”, gives the logging method, and it is cited here only for the log, not re-written. Second, keep the stranded boards physically separate from good boards until each one has a disposition, and do not feed them back into the line unmarked. Third, do not start the oven again until the reason for the stop is understood: a board that is re-run through an oven that is about to stop a second time is a board that has been heated twice for nothing.
The mistake that costs the most boards is judging the batch as one thing. A reflow oven is a tunnel, and when the conveyor stops, the boards in it are standing at different points along the profile. One board is in the preheat zone with paste that has barely begun to warm. The next is in the soak zone, where its flux is being used up. The next is at peak, where its solder is half melted and its joints are half formed. The next is in cooling, where its joints were already made and are now solidifying at whatever rate the cooling oven happens to coast down at. They have had different thermal histories, so a single decision — re-run the batch, or scrap the batch — is wrong for most of the boards in it.
Even boards at the same nominal position are not identical. A board’s coldest joint may never have reached liquidus while its hottest point was already near a component’s limit, because large parts heat more slowly than small ones and because no board heats perfectly evenly. That is why a profile is judged thermocouple by thermocouple, never by average — the rule our profiling checklist, “Reflow Oven Temperature Profiling”, sets out for a planned profile, and it applies just as strictly to a board that was interrupted. The position of the board in the tunnel and the reading from its own thermocouples are the two facts the whole disposition decision is built on, and if neither was recorded, the first job is to reconstruct them as well as the oven log and the recipe allow, not to guess.
There is one more reason the batch cannot be judged as a whole: the boards do not all carry the same components. A board full of small chip parts and a board carrying a large ball-grid array or a moisture-sensitive package have different limits, different failure modes and different inspection needs after a second heat exposure. The disposition is per board, per component set, and per measured profile — never per lot.
To judge a stranded board you have to know what each stage of the profile does, and what interrupting it leaves behind. A normal lead-free profile has four stages, and the numbers below are the typical SAC305 starting references used on the R10 product page and in our profiling checklist — ramp 1–3 °C per second, soak 150–200 °C for 60–120 seconds, peak 235–250 °C above the 217 °C liquidus, cooling 2–4 °C per second. They are starting references, not a recipe, and the paste datasheet governs in every case. What matters here is not the numbers themselves but what is happening to the paste and the joints at each stage when the oven stops.
| Where the board stopped | What the paste and joints look like | What it means for the board |
|---|---|---|
| Preheat, before soak | Paste still largely unmelted grey powder held in flux; solvents partly driven off; flux only partly activated; no joint formed yet | Least thermal damage of any stop position. The paste has not formed a joint, so there is nothing half-formed to undo — but the board has still had one heat exposure, and its flux and its components’ limits must still be checked before any re-run |
| Soak | Board near uniform temperature but below liquidus; flux active and being consumed; no melting yet | The dangerous middle ground. A prolonged hot hold here can consume the flux before the solder ever melts, which is the failure described in section 4 |
| Peak, at or just past liquidus | Paste partly or fully melted; wetting in progress; the intermetallic layer forming at the pad and component interfaces | The worst position to be stranded in. If the board then cools uncontrolled, its joints solidify from an incomplete profile — partial wetting, possible graping and cold joints. Paste that never fully coalesces is a defective condition under IPC-A-610, even if a fillet looks acceptable |
| Cooling zone | Joints already formed, but solidifying outside the controlled cooling rate — either coasting down slowly with the oven, or quenched fast if the cover is opened and the board pulled out hot | Cooling rate sets grain structure: too fast can crack joints or warp the substrate; too slow grows a coarser grain and a thicker intermetallic layer. Neither matches the profile the joints were qualified against |
| Any zone, long hot dwell | Board and components keep absorbing heat while stationary: flux exhausted, exposed solder and bare pads oxidising, intermetallic still growing while the solder is molten | The longer a board sits hot, the worse its starting point for any second attempt. The intermetallic layer itself is essential to the bond — its presence is not a defect — but a thicker layer grown by extra time molten is a reliability concern, and no published number gives a safe thickness limit for a stranded board |
Two things in that table deserve emphasis, because they are the two errors most often made at the bench. First, a board that stopped before liquidus is not automatically a board that can simply be run again: it has still consumed flux, still heated its components, and still used up part of whatever reflow-pass allowance those components carry. Second, a board that stopped after its joints were formed is not automatically a good board: its joints solidified under conditions nobody qualified, and appearance alone does not prove a compliant joint. Both need the checks in sections 5 to 7, not a glance.
The most useful single observation on a stranded board is also the easiest to misread. Paste that never fully coalesced — grainy, rough, ball-like instead of one homogeneous molten volume — can mean two opposite things, and the two have opposite fixes. Either the board never got hot enough, in which case the flux is still there and a second, properly controlled pass may complete the job; or the board got too hot for too long, the flux was consumed before the solder melted, and the solder can no longer wet the oxidised surfaces no matter how it is reheated. Industry experts call the second condition “too hot, too long”, and it is the opposite of a too-cool condition. A profile record tells them apart. Eyes alone do not.
Flux’s job is to remove surface oxides so molten solder can wet. It is consumed during heating, and a soak that runs too long — or a board held hot without reaching liquidus — can exhaust flux activity before the solder melts. Once flux is spent, exposed molten or hot solder and bare pads oxidise, and oxidised pads will not wet on a second attempt without re-conditioning. Practitioners report the same point from the repair bench: a secondary reflow often works, but it will not work when pads have high oxidation levels, and the reliable fix then is to remove the component, condition the pads — remove the oxidation and tin them — and reinstall it. Reheating a board whose flux is already spent does not restore the flux; it only adds another heat cycle to the damage.
| What you see | What it suggests | What to check before deciding |
|---|---|---|
| Paste still grey, powdery, individual solder spheres visible, no coalescence | Never reached liquidus; proper intermetallic not formed at either interface | The board’s profile record: did any point reach liquidus? Is the flux still active per the paste datasheet, or was it spent in a long hot hold? |
| Paste partly melted, dull and rough, partially coalesced | Flux exhaustion or under-heating — opposite causes | The profile record is the only thing that tells them apart. Do not choose a fix by appearance |
| Joints fully formed, shiny, well-wetted fillets | Joints may be acceptable — but only inspection and test can confirm it | AOI, X-ray for hidden joints, and electrical test after any re-run; appearance alone does not prove a compliant joint |
| Tombstoning, solder balling, bridging, shifted parts | Uneven heating or wetting imbalance | A second pass with the same profile will likely repeat the defect. Fix the cause first, or the re-run is a second failure |
| Discoloration of board or solder mask, scorched flux residue, dull grey joints after a long hot dwell | Overheating or multiple heat cycles; possible laminate or mask damage | Inspect for delamination and pad damage before any re-run decision |
| Delamination, blistering, lifted pads, pad cratering, cracked packages | Scrap or material-review decision — not re-runnable | No re-run. A second cycle makes moisture-driven delamination worse, not better |
| Hidden joints (BGA, QFN bottom terminations) | Visual inspection cannot judge them at all | X-ray is required before any re-run or scrap call on those packages |
One qualification belongs here, because it is where good boards are most often lost: roughness on the land alone, with a properly wetted and formed fillet, is a process indicator, not automatically a failed joint. The table above is a guide to what to check, not a pass/fail rule, and every row ends in a check rather than a verdict.
Every engineer who has stood in front of a stopped oven has asked the same question: can these boards just go through again? The honest answer is that no published source gives a single safe temperature, time or profile for re-running a partially reflowed board, and anyone who quotes one is inventing it. The industry standards point the decision back to three board-specific documents, and the viable window is the overlap of all three: the solder paste manufacturer’s datasheet window, each component’s datasheet temperature limit and permitted reflow-pass count, and the board’s own measured profile from its thermocouples. If those three do not overlap, the board is not a re-run candidate, and no generic recipe can make it one.
The standards are explicit about what they do not say. IPC-7095, the design and assembly guidance for ball-grid arrays, is guidance only: it directs accept and reject requirements to J-STD-001 and IPC-A-610, and it gives no single rework-count limit for every package and laminate. IPC-7711/7721, the rework and repair standard, sets out how rework is done — including hot-air removal, re-balling, cleaning and bake pre-heat — but its scope does not limit the maximum number of times an assembly may be reworked or repaired; the count limit must come from the customer’s specification or the house rule. The most common line practice reported is one rework per position, but that is a reported practice, not a standard, and the customer’s specification governs.
The strongest explicit number found anywhere comes from a single component manufacturer, and it shows exactly why a generic number cannot be borrowed. AMD’s soldering guidelines state that, following the initial placement and reflow, its devices must not be reflowed more than two additional times and must not be removed from the board, with a peak body temperature not above 250 °C for lead-free packages. That is AMD’s limit for AMD devices. It is not a universal rule for all components, and this article presents it only as an example of the kind of limit a component datasheet carries — never as “boards may be reflowed twice more”. Every other component on the board carries its own limit, and the strictest one governs.
A re-run is not a second side. A planned second reflow pass in double-sided assembly — the subject of the WordPress piece “Double-Sided SMT Assembly: How the First Side Survives the Second Reflow” (17 November 2026) — is designed in advance: the first-side joints re-melt by design and the parts are held by surface tension. An interrupted first pass is not that. A re-run after an interruption is an unplanned second heat exposure on joints that were never meant to be re-melted, decided under the three documents above, and it must never be justified by saying “double-sided boards go through twice”.
So the re-run test, stated plainly, is this: a board is a re-run candidate only when its paste is unmelted or its joints are incomplete and its flux is not exhausted and every component on it is still inside its permitted pass count and temperature limit and its own measured profile shows no point exceeded a component limit. A full-profile re-run is then required — a complete pass judged against the paste datasheet, not a “top-up” heat — followed by the full inspection and test in section 7. Anything less than that test is a guess, and a guess is what this article is written to replace.
With the checks from sections 4 and 5 in hand, the boards sort themselves into three rungs. The ladder below is a framework assembled from practitioner guidance — it is not an IPC rule, and no standard publishes a ladder like this. Treat it as a way to organise the decision, not as a rule that decides for you.
| Disposition | The board looks like this | What happens next |
|---|---|---|
| Re-run candidate | Stopped before liquidus, paste unmelted, flux not exhausted, all components inside pass-count and temperature limits, moisture clocks still valid | Full-profile re-run against the paste datasheet, then full inspection and electrical test (section 7). Recorded as a re-run sub-lot, never mixed back silently |
| Component-level rework | Localised defect on an otherwise good board — a single open joint, a bridge, a head-in-pillow ball — with pads intact and no laminate damage | Remove the component, condition the pads, reinstall per the IPC-7711/7721 method. One rework per position is the common line rule; the customer’s specification governs. After one failed secondary reflow attempt, remove and investigate rather than heating again |
| Scrap or material review | Delamination, lifted or cratered pads, cracked or popcorned packages, several defects across one package or site, oxidation too heavy for wetting, or any component already beyond its permitted reflow count or temperature limit | No re-run and no routine rework. Hold for the material review board’s decision. Two removals on one site is outside what the rework standard covers |
Two examples show how the ladder works in practice, both marked as examples, not records. First, a board that stopped in preheat with powdery paste, a clean profile record showing no point near any component limit, and a paste datasheet that allows a second heat exposure: a re-run candidate, provided it passes the inspection in section 7 afterwards. Second, a board that stopped at peak and cooled uncontrolled, with one ball-grid array showing a single open ball on X-ray and no pad damage: a rework candidate for that one package, not a whole-board re-run, because heating the entire board again would put every other component through a second cycle to fix one joint. And the board that stopped at peak, sat hot for an hour while the oven was diagnosed, and now shows a cracked package and a blistered laminate: scrap or material review, whatever the rest of the batch looks like.
The money side of this ladder is deliberately not priced here. Whether a rework is worth doing, and what a scrapped board costs, is a costing decision, and our piece “What a Bad Board Really Costs” prices the scrap, rework and return options in cost units without re-stating them here. The ladder above decides on technical grounds only: can this board still become a good board, and what evidence would prove it?
A re-run board is not a good board until it has been proven one. Reworked boards must be re-inspected and then electrically or functionally tested before release, and the same rule applies to re-run boards: visual inspection first, automated optical inspection next, X-ray for any hidden joint, and electrical or functional test last. A joint that looks acceptable can still be defective — incomplete reflow is a defective condition even when a fillet looks formed — and only the inspection and the test together close the question. If a re-run board fails at any of those steps, it goes back to the ladder in section 6; it does not go through the oven a third time on the hope that the next pass fixes it.
Segregation is not paperwork for its own sake. Re-run and reworked boards must be kept as a traceable sub-lot, with their own route card or tray, and never mixed back into the good population unmarked. If a field failure ever traces back to one of these boards, the difference between a contained sub-lot and a mixed population is the difference between recalling a handful of boards and recalling a whole order. The record for each board needs eight fields, and nothing less will do the job later:
Per-board disposition record — eight fields
Board ID and batch · position in the tunnel when the oven stopped · time in the oven and the recipe that was running · profile record (or the reason there is none) · inspection results (visual, AOI, X-ray where used) · disposition (re-run, rework, scrap, hold) and the evidence for it · test result after re-run or rework · who decided, and when. Keep the record with the sub-lot, not in a notebook that leaves the line.
One more discipline belongs here: the person who decides a board’s disposition should not be the only person who checks it. Rework guidance from the repair industry is explicit that rework and re-check should be done by different people, and the same separation protects a re-run decision. The operator who pulled the boards out of a hot oven is the worst person to be the sole judge of whether they are good.
While the disposition is being decided, a second clock is running that has nothing to do with the oven. Moisture-sensitive components carry a moisture sensitivity level, an MSL rating from 1 to 6 assigned by the component manufacturer under IPC/JEDEC J-STD-020, which states how long a non-hermetic surface-mount device can sit in factory air before it must be soldered or baked. The floor-life clock starts when the moisture-barrier bag is opened, exposure is cumulative, and resealing a bag stops further absorption but does not remove the moisture already absorbed — only a qualifying bake resets the clock. The standard’s classification figures are shown below as the standard’s figures, not as a re-run rule: the rating that governs a real board is the one on that component’s own datasheet.
| MSL rating | Floor life in factory air (J-STD-020 classification) |
|---|---|
| MSL 1 | Unlimited |
| MSL 2 | 1 year |
| MSL 2a | 4 weeks |
| MSL 3 | 168 hours |
| MSL 4 | 72 hours |
| MSL 5 | 48 hours |
| MSL 5a | 24 hours |
| MSL 6 | Mandatory bake before use |
The mechanism is simple and unforgiving: moisture absorbed into a package flashes to steam above roughly 200 °C in reflow, and the steam delaminates the package or cracks it from the inside — the failure called popcorning. A board stranded by a stop has already given its components one heat exposure; if it then sits in factory air while the disposition is argued over, the floor-life exposure keeps accumulating for any component that has not yet been soldered, and a second pass is often the one that pops a package that survived the first. That is a reasoning consequence of the mechanism, not a measured study — no study of boards stranded by an oven stop was found anywhere — but it is the reason a disposition decision should not wait for a convenient moment. Do not invent a “safe waiting time” for stranded boards: the only citable numbers are the per-device floor-life figures above, and the bake conditions that reset the clock come from the component manufacturer and J-STD-033, by package thickness. One more distinction matters: the classification testing in J-STD-020 runs samples through up to three reflow passes at the classification peak temperature, and that is a test, not permission to reflow production boards three times.
Some of the damage in this article is preventable by the oven, and some of it is not, and the line between the two is worth stating exactly. The JHIMS R10 reflow oven, as its product page states, is a 20-zone lead-free hot-air oven — ten upper and ten lower zones, independently controlled, PID closed-loop with ±1 °C accuracy, a 3,840 mm preheat tunnel, a 1,260 mm cooling section with three upper and three lower zones, a maximum board width of 460 mm, 25 mm component clearance top and bottom, and a transport speed of 300–2,000 mm per minute. Those are the page’s stated specifications, and they are cited here as the page states them.
Directly relevant to a mid-run stop is the R10’s integrated uninterruptible power supply. The product page states that the UPS continuously monitors the main power input and, in the event of a power outage, engages within milliseconds to provide backup power specifically to the transport conveyor system, so that all boards inside the furnace are transported out of the heating tunnel before the furnace cools. That is a product feature for one cause of stop — a power outage — and for one system — the conveyor. It is not a guarantee for other stop causes: a conveyor fault, a temperature fault, an operator stop or a board jam leaves the boards where they stopped, and the disposition in sections 5 to 7 still has to be made. The R10 page also states that the oven logs full production data with timestamps — zone temperatures, speed, recipe and board counts — which is exactly the record section 1 asks for, if the line uses it.
What the oven cannot do is decide for you. No oven knows the paste datasheet, the component limits or the moisture clocks on the boards inside it, and no oven can inspect a joint. That decision is the line’s, and it is made with the three documents in section 5 and the inspection in section 7. JHIMS sells the R10 reflow oven; it does not sell a rework or re-run service, and this article is a decision guide, not a service offer. For the oven itself, the planned side of the story belongs to our maintenance calendar piece — planned checks, per the oven manufacturer’s plan, are planned time, not downtime — and this article is the unplanned stop, not the calendar.
1. Judging the batch as one lot. Re-running every board because most of them stopped early, or scrapping every board because one of them stopped at peak. Boards at different tunnel positions have different thermal histories; judge them one by one.
2. Deciding by appearance alone. A shiny fillet does not prove a compliant joint, and a rough paste surface does not by itself say whether the cause was under-heating or flux exhaustion. The profile record and the inspection decide; eyes only start the question.
3. Reaching into a hot oven. Pulling boards out by hand before the cool-down the manual specifies. The burn risk is the immediate cost; the uncontrolled quench the boards get on the way out is the hidden one.
4. Heating the same board again to fix one joint. A whole-board re-run to repair a single open ball puts every other component through a second cycle for one joint’s sake. Localised defects get component-level rework; the whole board gets a re-run only when the whole board qualifies for one.
5. Mixing re-run boards back into the good population. No sub-lot, no record, no traceability. If one of those boards fails in the field, the line cannot tell which boards were re-run and which were not — and the customer cannot be told either.
Bottom line: A stopped oven does not damage a batch; it damages individual boards, each in its own way, according to where it sat and how far through its profile it got. Stop safely, record the stop, and keep the stranded boards separate. Then decide board by board against three documents — the paste datasheet, the component datasheets, and the board’s own measured profile — because no single temperature, time or profile is a safe re-run standard for every board. Re-run the candidates through a full profile, rework the localised defects at component level, and send the delaminated, cracked and over-exposed boards to scrap or material review. Inspect and test everything that goes back into the line, keep it as a marked sub-lot, and write the record down. The boards you save that way are the ones you can prove are good.
Can a board that stopped in the oven simply go through again?
Sometimes, and only after the three-document test: the paste datasheet must allow a second heat exposure, every component must still be inside its permitted pass count and temperature limit, and the board’s own measured profile must show no point exceeded a component limit. If any one of the three fails, the board is not a re-run candidate. There is no published single temperature or time that makes a re-run safe for every board.
The paste still looks powdery. Does that mean the board is fine to re-run?
Not by itself. Powdery, uncoalesced paste means the board never reached liquidus, which is the least damaged starting point — but the flux may already be spent if the board sat hot for a long time, and its components have still had one heat exposure. Check the profile record and the paste datasheet before deciding; a second pass on oxidised pads will not wet.
The joints look shiny and well formed. Can the board ship?
Not on appearance alone. Joints that solidified outside their qualified cooling rate need the full check: visual inspection, AOI, X-ray for hidden joints, and electrical or functional test. Incomplete reflow is a defective condition even when a fillet looks acceptable.
How many times can a board be reflowed in total?
There is no universal number. IPC-7711/7721 sets no maximum rework count; the limit comes from the customer’s specification or the house rule. Component manufacturers set their own limits — AMD, for example, allows its devices at most two additional reflows after the initial pass — and the strictest component on the board governs. Do not quote any manufacturer’s number as a general rule.
Does the R10’s UPS mean a power cut cannot damage boards?
No. The R10’s integrated UPS powers the transport conveyor on a power outage so boards are carried out of the heating tunnel before it cools — that is what the product page states, for a power outage and for the conveyor only. It does not cover a conveyor fault, a temperature fault, an operator stop or a board jam, and it is not a guarantee that no board is ever damaged. For any other stop cause, the disposition in this article still has to be made.
Talk to JHIMS about your reflow line. JHIMS builds the R10 lead-free hot-air reflow oven and the SMT line around it — placement, printing, inspection and handling. If you are setting up a line, replacing an oven, or want the R10’s specifications and the profile data behind them, contact us at [email protected]. For the oven itself, see the R10 reflow oven product page; for how to judge a board’s thermal exposure, see our profiling checklist Reflow Oven Temperature Profiling; for how to log the stop itself, see Where the Hours Go: Logging SMT Line Downtime; for the planned maintenance that keeps stops rare, see A Preventive Maintenance Calendar for Your SMT Line; and for the costing side of the scrap-versus-rework decision, see What a Bad Board Really Costs.